Automation Relay,Circuit Breaker,Contactor,Isolation Switch,Light,Other Electrical Equipment,Pneumatic,Power Quality,Solar Energy Storage System,Surge Protection Device,Timer Switch,Topsales Products,Transfer Switch,Ungrouped
Contact parameter | ||||
Main contact | Rated operational current le | 250A | ||
Rated operational voltage Ue | 12~1000 VDC | |||
Min.load | 1A12VDC | |||
Main contact type | 1SH(SPST NO DM) | |||
Nominal resistance of main circuit | 0.2mΩ(@250A) | |||
Main contact mounting | M8 external thread | |||
Connecting torque | 10~12 N·m | |||
Max.switching current (more than one cycle) | 2500A320VDC | |||
Auxiliary contact | Max.current | 30VDC 2A;125VAC 3A | ||
Min.current | 8VDC 100mA | |||
Contact resistance | <0.150 | |||
Coil parameter | ||||
Rated voltage Us | 12/24VDC | |||
Operational voltage Range | 8~36 VDC | |||
Pick up voltage | 7~8 VDC | |||
Release voltage | 5~6 VDC | |||
Coil power | keeping:2W | |||
Inrush current | 3A(0.1s)(@12v) | |||
Holding current | 0.17A@12V; 0.085A@24V | |||
Close time(@Us) | ≤45ms | |||
Release time(@Us) | ≤10ms | |||
Bounce time(@Us) | ≤5ms |